Hi Carl, Thanks for your suggestion.
We missed out activating AutoPilot-AD-Utilities module over the grid which was causing the issue. As soon as we activated it, we were able to monitor the messages and were able to retrieve correlationid and append to a notepad. So finally the steps for jms monitor adapter which would be listening to weblogic queue are: 1. Configure monitor adapter for the particular queue. 2. Create an AO workflow which would be doing transformation on inputevent context item and writing it to a text file using file adapter. 3. Create a rule by providing the xml from gid.log after "Sending event to adapter manager" text 4. Export the module to repository. 5. Activate the imported module along with any AutoPilot module being used in the workflow. 6. Post messages in the weblogic after restarting the CDP. 7. Check the text file. Thanks & Regards, Saurabh -- View this message in context: http://ars-action-request-system.1.n7.nabble.com/JMSMonitorAdapter-Error-in-AO-A-request-was-sent-to-a-remote-peer-and-a-response-was-not-received-prt-tp112117p112280.html Sent from the ARS (Action Request System) mailing list archive at Nabble.com. _______________________________________________________________________________ UNSUBSCRIBE or access ARSlist Archives at www.arslist.org "Where the Answers Are, and have been for 20 years"