Dňa Št, 2003-09-04 at 11:40, Jamie Neil napísal: > Simone Vasoli (BK s.r.l.) wrote: > > Hi, > > when I make a call, chan_capi always uses controller 2, and never uses > > controller 1 (so I have 4 lines for incoming calls, but only 2 lines > > instead of 4 for outgoing calls). > > > > this is with 2 AVM Fritz cards PCI. > > You can only use one Fritz PCI card per box due to a limitation built > into the AVM CAPI driver. > check this link - is describe how to use more than one fcpci in pc. I personally use 3 cards im my computers, without problems...
http://www.quiss.org/caiviar/Two-Fritzcards-HOWTO > However you can get around this by hacking the (binary) fcpci kernel > module and changing the name of second and subsequent modules. I haven't > tried it personally, but I think there are several people who are using > this technique sucessfully :). > > Just in case anyone is interested, AVM also say that you can't use the > Fritz card and the B1 card in the same box. However I have found it > seems to work fine provided the B1 CAPI driver is loaded *after* the > Fritz driver. -- SUNTEQ s. r. o. Hviezdoslavova 9 # Prievidza # 971 04 # Slovak republic Tel: +421-46-5430 754 # Fax: +421-46-5439 144 http://www.sunteq.sk/ ------------------------------------------------------------ A mind is like a parachute... it only works when it's open. _______________________________________________ Asterisk-Users mailing list [EMAIL PROTECTED] http://lists.digium.com/mailman/listinfo/asterisk-users