On Tuesday, Nov 4, 2003, at 13:54 America/Chicago, Brian D Heaton wrote: <stuff deleted for brevity>
<more stuff deleted>If you can take it out of service for a bit I'd pop a loopback up using on the RJ45 side of the balum (baloon) and see if they can run a clean BERT to that for about an hour. If you've got an intermittent problem you should at least take a few CRCs in that time period.
Just a terminology pedant (sorry in advance)...
It should be "balun" from the 2 words balanced and unbalanced as it is a "converter" between the two. Coax is "unbalanced" i.e. one side is grounded (the shield on the coax) and the RJ-45 side is balanced as each pair is rx+ and rx- and tx+ and tx- with no ground to be seen.
Later; Tim