On Sun, 6 Aug 2006, Stefan-Michael. Guenther (in-put GbR) wrote: > > > Protocol error layer 1 (broken line or B-channel removed by signalling > > > protocol) > > > > This is the cause of your problem! Your physical ISDN connection is > > broken. Maybe your cross/NT connection is not setup correct. > > > okay, then one last question before I start testing all the options in the > configuration menu of the EICON card: > > Is this error caused by the port where the fax comes in (ISDN4/port 4) or by > the outgoing port (ISDN3/port 3)?
It looks like ISDN3, but you can check this by running divactrl mlog -c 3 -o and/or divactrl mlog -c 4 -o to see the cards logs. > P.S: I have spent about two weeks now on this topic, together with the really > helpful support from EICON. If I finish this configuration successfully, I > promise I will write a HOWTO on it and post the link on the list;-)) We can add this to the melware.org wiki then.... Armin _______________________________________________ --Bandwidth and Colocation provided by Easynews.com -- asterisk-users mailing list To UNSUBSCRIBE or update options visit: http://lists.digium.com/mailman/listinfo/asterisk-users