Hi Mike,
Your log seems to be incomplete. It stops in the middle of the call.
Regards,
Steve
Mike Heininger wrote:
Hi,
I am trying to receive a fax with the spandsp library.
The sending fax says "success" but there is no tiff file generated.
I use "exten => 7000,1,rxfax(/tmp/testfax.tif)" in my extensions.conf.
The connection is via SIP/G.711 as I have read on the list that this
can sometimes work (I know Fax over IP is troublesome without T.38).
I think the transmission should not be the problem because of the
"success" on the sending fax.
This is the debug output.
Am I missing something?
TIA,
Mike
*CLI> -- Executing RxFAX("SIP/uid-c5b6", "/tmp/testfax.tif") in new
stack
Changed from phase 0 to 1
Slow carrier up
Slow carrier down
Slow carrier up
Slow carrier down
Slow carrier up
Slow carrier down
Start receiving document
Changed from phase 1 to 4
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Minimum scan line time for higher resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
HDLC underflow in state 9
Changed from phase 4 to 3
Slow carrier up
Slow carrier down
T4 timeout in state 9
Changed from phase 3 to 4
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Minimum scan line time for higher resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
T2 timeout
Start receiving document
Sending ident
>>> CSI: 40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
DIS:
Preferred octets: 256
Can receive fax
Supported data signalling rates: V.27ter and V.29
R8x7.7lines/mm and/or 200x200pels/25.4mm OK
2D coding OK
Scan line length: 215mm
Recording length: A4 (297mm)
Receiver's minimum scan line time: 0ms at 3.85 l/mm: T7.7 = T3.85
R8x15.4lines/mm OK
Minimum scan line time for higher resolutions: T15.4 = T7.7
>>> DIS: 80 00 ce f0 80 80 01
HDLC underflow in state 9
Changed from phase 4 to 3
_______________________________________________
Asterisk-Users mailing list
[EMAIL PROTECTED]
http://lists.digium.com/mailman/listinfo/asterisk-users
To UNSUBSCRIBE or update options visit:
http://lists.digium.com/mailman/listinfo/asterisk-users