We are getting "The number of files mismatch!" error when a job tries to 
append to a tape in V1.38.11.

We did not see this until adding a LTO changer with 2 drives(and 
increasing max concurrent jobs).   I set max concurrent to 1, everywhere 
I could find and will see if it fixes it.

I've read through this 
http://bacula.org/rel-manual/Tips_Suggestions.html#SECTION000357000000000000000 
and I wonder if anyone else is having this issue or could provide some 
insight to fixing it?

20-Nov 22:44 wcsan1-dir: Recycled volume "Logs-0001"
20-Nov 22:47 wcsan1-dir: Start Backup JobId 456, 
Job=wcsan1.2006-11-16_23.05.00
20-Nov 22:47 wcsan1-sd: 3301 Issuing autochanger "loaded drive 0" command.
20-Nov 22:47 wcsan1-sd: 3302 Autochanger "loaded drive 0", result is Slot 6.
20-Nov 22:47 wcsan1-sd: 3307 Issuing autochanger "unload slot 6, drive 
0" command.
20-Nov 22:49 wcsan1-sd: 3304 Issuing autochanger "load slot 1, drive 0" 
command.
20-Nov 22:50 wcsan1-sd: 3305 Autochanger "load slot 1, drive 0", status 
is OK.
20-Nov 22:50 wcsan1-sd: 3301 Issuing autochanger "loaded drive 0" command.
20-Nov 22:50 wcsan1-sd: 3302 Autochanger "loaded drive 0", result is Slot 1.
20-Nov 22:51 wcsan1-sd: Volume "Inc-0001" previously written, moving to 
end of data.
20-Nov 22:57 wcsan1-sd: wcsan1.2006-11-16_23.05.00 Error: I cannot write 
on Volume "Inc-0001" because:
The number of files mismatch! Volume=14 Catalog=15
20-Nov 22:57 wcsan1-sd: Marking Volume "Inc-0001" in Error in Catalog.
20-Nov 23:00 wcsan1-dir: Recycled volume "Inc-0002"
20-Nov 23:00 wcsan1-sd: 3301 Issuing autochanger "loaded drive 0" command.
20-Nov 23:00 wcsan1-sd: 3302 Autochanger "loaded drive 0", result is Slot 1.
20-Nov 23:00 wcsan1-sd: 3307 Issuing autochanger "unload slot 1, drive 
0" command.
20-Nov 23:02 wcsan1-sd: 3304 Issuing autochanger "load slot 2, drive 0" 
command.
20-Nov 23:02 wcsan1-sd: 3305 Autochanger "load slot 2, drive 0", status 
is OK.
20-Nov 23:02 wcsan1-sd: 3301 Issuing autochanger "loaded drive 0" command.
20-Nov 23:02 wcsan1-sd: 3302 Autochanger "loaded drive 0", result is Slot 2.
20-Nov 23:03 wcsan1-sd: Recycled volume "Inc-0002" on device "Drive-1" 
(/dev/nst0), all previous data lost.
21-Nov 00:38 wcsan1-dir: Bacula 1.38.11 (28Jun06): 21-Nov-2006 00:38:13


-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys - and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to