On Feb 1, 2008 2:32 PM, Robin Blanchard <[EMAIL PROTECTED]> wrote:
> > : It does....I successfully wrote to the tape this morning. Now I'm
> > trying
> > : to get the barcode/label business going.
> >
> > So did it really change the tapes, or just wrote to the tape?
> > Tape drive and tape changer are different scsi devices.
> >
>
> Well that's exactly what I'm tyring to figure out :) the btape full
> multitape test completed successfully. But this morning's "real" test
> terminated (and I received no email from bacula). So I figured perhaps
> the problem is/was changing of tapes (hence starting over and attempting
> to use the barcode labels)...
>

Yes. You need to get the label barcodes working because you should
never manually label tapes in an autochanger that has a barcode
reader. If you label the tapes manually you are disabling the
advantage of having a barcode reader to tell bacula what tapes are in
each slot.