== Autochanger test ===
> 
> 3301 Issuing autochanger "loaded" command.
> Nothing loaded in the drive. OK.
> 3303 Issuing autochanger "load 1 0" command.
> 
> It just sits there doing nothing, I guess it is supposed to remove the tape 
> from the drive and put the tape from slot 1 into the drive but that doesn't 
> seem to happen

I've been using a 124T with Bacula for a little more than a year now.

I noticed that right after the powering on and every time a tape has
been accessed the library has a certain tendency to reply with garbage
to the first changer command it gets; I don't know if it's my particular
unit/setup or if other 124Ts do that.

I never got down to debugging the issue; adding a

${MTX} -f ${ctl} status >/dev/null 2>&1

before every mtx invocation in the mtx-changer script got it working
with Bacula.

HTH,
Andrea

------------------------------------------------------------------------------