Hi Rob,

I updated the slots. THEN (yes, yes, shame on me) I checked the messages. In my email below I reacted to an error messages via email... It seems as there was a time out when loading the tape, which was recovered by after some time:


05-Aug 16:09 -sd JobId 908: 3305 Autochanger "load Volume 000023L9, Slot 17, Drive 0", status is OK. 05-Aug 16:09 -sd JobId 908: Warning: mount.c:216 Open of Tape device "LTO9-1" (/dev/nst0) Volume "000023L9" failed: ERR=tape_dev.c:169 Unable to open device "LTO9-1" (
/dev/nst0): ERR=Eingabe-/Ausgabefehler

05-Aug 16:09 -sd JobId 908: Warning: mount.c:216 Open of Tape device "LTO9-1" (/dev/nst0) Volume "000023L9" failed: ERR=tape_dev.c:169 Unable to open device "LTO9-1" (
/dev/nst0): ERR=Eingabe-/Ausgabefehler

05-Aug 16:09 -sd JobId 908: Warning: mount.c:216 Open of Tape device "LTO9-1" (/dev/nst0) Volume "000023L9" failed: ERR=tape_dev.c:169 Unable to open device "LTO9-1" (
/dev/nst0): ERR=Eingabe-/Ausgabefehler

05-Aug 16:09 -sd JobId 908: Warning: mount.c:216 Open of Tape device "LTO9-1" (/dev/nst0) Volume "000023L9" failed: ERR=tape_dev.c:169 Unable to open device "LTO9-1" (
/dev/nst0): ERR=Eingabe-/Ausgabefehler

05-Aug 16:09 -sd JobId 908: Warning: mount.c:216 Open of Tape device "LTO9-1" (/dev/nst0) Volume "000023L9" failed: ERR=tape_dev.c:169 Unable to open device "LTO9-1" (
/dev/nst0): ERR=Eingabe-/Ausgabefehler

05-Aug 16:09 -sd JobId 908: Please mount append Volume "000023L9" or label a new one for:
   Job:          FileServer_Full.2024-08-02_23.05.00_06
   Storage:      "LTO9-1" (/dev/nst0)
   Pool:         Tape
   Media type:   LTO-9
05-Aug 16:14 -sd JobId 908: Error: tape_dev.c:169 Unable to open device "LTO9-1" (/dev/nst0): ERR=Eingabe-/Ausgabefehler 05-Aug 16:14 -sd JobId 908: Recycled volume "000023L9" on Tape device "LTO9-1" (/dev/nst0), all previous data lost. 05-Aug 16:14 -sd JobId 908: New volume "000023L9" mounted on device "LTO9-1" (/dev/nst0) at 05-Aug-2024 16:14. 05-Aug 16:40 -sd JobId 908: Despooling elapsed time = 00:52:58, Transfer rate = 314.6 M Bytes/second
05-Aug 16:40 -sd JobId 908: Spooling data again ...
05-Aug 17:55 -sd JobId 908: User specified Job spool size reached: JobSpoolSize=1,000,000,237,237 MaxJobSpoolSize=1,000,000,000,000 05-Aug 17:55 -sd JobId 908: Writing spooled data to Volume. Despooling 1,000,000,237,237 bytes ...



Still confused about the error message, but it seems as there are some self-healing capabilities involved.

Regards

Thorsten

Rob Gerber schrieb am 05.08.24 um 18:24:
When I have seen this before it is becuase bacula has old information about the tape location. Like if the tape was added to the changer or moved to a different slot using the tape changer web interface or front panel, but bacula's knowledge of tape inventory was not refreshed. In those cases i have ran an 'update slots' operation from the bacularis volumes tab. Please note that it is necessary to specify the entire range of available slots (in my case, '1-24'). The default slot value '0' does not mean 'refresh all slots' in my experience.


In these cases I have also had good results manually moving the necessary tape to the drive. After about 5 minutes or so bacula should recognize that the correct media has shown up in the drive and resume the job(s) that are waiting for that media. However, I am not sure if the bacula tape inventory will remain out for date after the backup operation finishes. An update slots task might still be necessary.

You should also be able to do an update slots task from bconsole, but I'm unfamiliar with the exact syntax.

Robert Gerber
402-237-8692
r...@craeon.net

On Mon, Aug 5, 2024, 12:08 PM Dr. Thorsten Brandau <thorsten.bran...@brace.de> wrote:

    Hi
    I get this message:

    05-Aug 16:09 -sd JobId 908: Please mount append Volume "000023L9" or label 
a new one for:

    and I am confused.

    Webin shows me the volume available in the pool:


        000023L9        LTO-9   2024-08-05 16:14:36     2024-08-05 16:39:38
    485996102656        Append

    So, what specifically can I do now? Bacula should load the volume by 
itself, doesn't it?

    Regards

    Thorsten

    _______________________________________________
    Bacula-users mailing list
    Bacula-users@lists.sourceforge.net
    https://lists.sourceforge.net/lists/listinfo/bacula-users


--
+ This Document is confidential + Dieses Dokument ist vertraulich +

->->-> Please register athttps://www.brace.de  for getting always the latest news and 
best informations! <-<-<-
* FOCUS Business Innovationschampion 2023, for development, prozesses, business 
model and organisation *
* Awarded as "Employer of the Future"
* WINNER OF THE EXPORT AWARD BAVARIA 2021 *
++++ Please visit us at those events:
* CosmeticBusiness, June 05 - June 06, 2024, Munich, Germany
*Microencapsulation Industrial Convention, July 22-25, 2024, Frankfurt, Germany*
*Food Ingredients Europe, Nov. 19-21, 2024 in Frankfurt, Germany*
++++

BRACE GmbH
Dr. Thorsten Brandau (thorsten.bran...@brace.de)
President
Am Mittelberg 5
D-63791 Karlstein
Germany
Tel: +49 6188 991757
Fax: +49 6188 991759
https://www.brace.de

HRB5004 (Amtsgericht Aschaffenburg), VAT DE151299833, Managing Directors: Dr. 
Thorsten Brandau

IMPORTANT NOTICE:
This email may be confidential, may be legally privileged, and is for the 
intended recipient only.
Access, disclosure, copying, distribution, or reliance on any of it by anyone 
else is prohibited
and may be a criminal offence. Please delete if obtained in error and email 
confirmation to the sender.

Attachment: smime.p7s
Description: Kryptografische S/MIME-Signatur

_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to