Wim,

VXLAN has a dedicated UDP port and is very clear in the RFC7348
[Lucy] This does not prevent other implementation to use VXLAN with other UDP 
port. If someone wants to stick on the dedicate UDP port, we can use the src 
UDP port to achieve that.
The proposal I gave works with an IP data plane
[Lucy] I am not clear what is your proposal in this piled thread. Could you 
state or copy/paste again?

Lucy
Will write something on what I proposed when I get some time, not soon

From: Lucy yong <lucy.y...@huawei.com<mailto:lucy.y...@huawei.com>>
Date: Friday 13 November 2015 at 17:10
To: Wim Henderickx 
<wim.henderi...@alcatel-lucent.com<mailto:wim.henderi...@alcatel-lucent.com>>, 
Haoweiguo <haowei...@huawei.com<mailto:haowei...@huawei.com>>
Cc: "bess@ietf.org<mailto:bess@ietf.org>" <bess@ietf.org<mailto:bess@ietf.org>>
Subject: RE: draft-hao-bess-inter-nvo3-vpn-optionc

Hi Wim,

OptionC is very useful for DCI use case. In this case, multi-hop EBGP 
redistributes VN routes between the end NVEs in source and destination Ass, 
ASBRs do not maintain and distribute the VN routes; a tunnel is built between 
the end NVEs in source and destination Ass for traffic transport. Due to the 
different data planes in DC and WAN, the tunnel is stitched by several 
segments, IP tunnels are used in DCs, and MPLS tunnels are used in WAN.

Traditional OptionC requires end-to-end MPLS, which may fit to some DCI cases. 
However, there are many DCs that do not support MPLS data plane. This draft is 
to provide the solution for this use case.

Although VXLAN has UDP port number, if tunnel ingress and egress can negotiate 
to use another UDP port for the VXLAN encapsulation, I don’t see it breaks 
anything. Not sure if hw has this restriction either. Even yes, we can consider 
using UDP source port for this purpose. UDP source port is used for transit 
ECMP and filled by flow entropy, tunnel egress can determine the flow entropy 
value and inform tunnel ingress. Thus, tunnel egress (i.e. DC ASBR) can 
maintain UDP source port and MPLS label table; when DC ASBR receives a packet 
from NVE, by lookup the table, it gets the label for the packet, push the label 
on the packet before sending toward WAN.

Hope we together work out the solution for this valid use case and like to hear 
any better alternative.

Regards,
Lucy





From: BESS [mailto:bess-boun...@ietf.org] On Behalf Of Henderickx, Wim (Wim)
Sent: Thursday, November 12, 2015 11:00 PM
To: Haoweiguo
Cc: bess@ietf.org<mailto:bess@ietf.org>
Subject: Re: [bess] draft-hao-bess-inter-nvo3-vpn-optionc

The whole draft complicates any data plane we defined so far and since there is 
simpler solutions I don’t support this proposal.
Arguments have been given as to why.

From: Haoweiguo <haowei...@huawei.com<mailto:haowei...@huawei.com>>
Date: Friday 13 November 2015 at 02:44
To: Wim Henderickx 
<wim.henderi...@alcatel-lucent.com<mailto:wim.henderi...@alcatel-lucent.com>>
Cc: "bess@ietf.org<mailto:bess@ietf.org>" <bess@ietf.org<mailto:bess@ietf.org>>
Subject: RE: draft-hao-bess-inter-nvo3-vpn-optionc


Hi Wim,

It is used for layer 3 VPN CE device to visit IP based overlay data center 
network. For layer 3 traffic forwarding, the MAC address in VXLAN/NVGRE is 
restricted only in data center inside domain. For the traffic from data center 
inside to outside,  the inner MAC address(destination MAC is ASBR-d's MAC, src 
MAC is NVE's MAC) in VXLAN/NVGRE will be dropped at ASBR-d, only IP payload 
will continue to be carried into MPLS network. I can emphasize this point in my 
later version, it doesn't have much impact on the whole solution.

This draft also is suitable for VXLAN-GPE and MPLSoGRE/MPLSoUDP network to 
interconnect with MPLS VPN network. In VXLAN-GPE, it supports IP in IP 
encapsulation, so no inner MAC concerns.



Thanks,

weiguo

________________________________
From: BESS [bess-boun...@ietf.org<mailto:bess-boun...@ietf.org>] on behalf of 
Henderickx, Wim (Wim) 
[wim.henderi...@alcatel-lucent.com<mailto:wim.henderi...@alcatel-lucent.com>]
Sent: Thursday, November 12, 2015 22:33
To: bess@ietf.org<mailto:bess@ietf.org>
Subject: [bess] draft-hao-bess-inter-nvo3-vpn-optionc
I don’t support the adoption of this draft as a WG. There is a major flaw in 
this proposal:
Basically the encapsulation of VXLAN/NVGRE is incompatible with MPLS IP-VPNs. 
VXLAN/NVGRE contains a MAC address and IP-VPNs don’t. The draft does not talk 
about any of this and introduces a lot of complexity for nothing.

If we want to describe a model C VPN interconnect with a IP fabric in a DC I 
recommend to do an informational RFC that describes this using VXLAN-GPE, 
MPLSoGRE or MPLSoUDP encapsulation and retain the E2E MPLS label we defined in 
RFC4364.