Hi John,

I can add that the value is from 0 to 0x00ffffff, will that work?


Thanks,

Sami
On 2/21/17, 10:56 AM, "John E Drake" <jdr...@juniper.net> wrote:

>Sami,
>
>Snipped, comment inline
>
>Yours Irrespectively,
>
>John
>
>> >
>> >> Ethernet Tag ID 32-bit field MUST be set to the 24-bit VPWS service 
>> >> instance
>> identifier value."
>> >
>> >
>> >
>> >Ok, but you still didn’t mention how the 24-bit value is to be aligned in 
>> >the 32-
>> bit field.  I’m guessing there will be some 0-padding, but will that the at 
>> the
>> beginning or the end?
>> >
>> 
>> I made the VPWS service instance identifier a 32-bit value in the new draft.
>> 
>
>[JD]   I don't think you can do this as there are multiple implementations 
>that use 24 bits  
>