Hello Authors of draft-ietf-bess-rfc7432bis,

I have a query regarding the section of "Loop Protection" 
https://datatracker.ietf.org/doc/html/draft-ietf-bess-rfc7432bis-04.txt#section-15.3
 in the document.

There is a statement regarding the "process" to be restarted after retry-timer 
expires. Which "process" is being referred to here ?
Is it just ONLY the "loop-protection"
Or
the "complete process" of "MAC Duplication Handling + Loop-protection": 
implying both sections 
https://datatracker.ietf.org/doc/html/draft-ietf-bess-rfc7432bis-04.txt#section-15.1
 and  
https://datatracker.ietf.org/doc/html/draft-ietf-bess-rfc7432bis-04.txt#section-15.3
 in that order.

The reference text is as follows:

"   When the retry-timer R for M expires, the PE flushes M from the

   Bridge Table and the process is restarted."

Regards,
Saumya.