On Mar 26, 2012, at 11:30 AM, Carlos Ribas wrote:
> I accidentally changed the serial number to one bigger than 32 bits and now 
> I'm trying to reset the serial number. Following the manual of Bind9 I tried 
> to add 2147483647 (2ˆ31-1) to the number and reload the server, but my slave 
> is not updating to the new zone serial number.

Shut down the slave server(s).
Use scp or rsync to copy over the zone file, one with a corrected serial #.
Restart the slave server(s).

[ Is BIND putting SOA serial #'s into a signed int? ]

Regards,
-- 
-Chuck

_______________________________________________
Please visit https://lists.isc.org/mailman/listinfo/bind-users to unsubscribe 
from this list

bind-users mailing list
bind-users@lists.isc.org
https://lists.isc.org/mailman/listinfo/bind-users