Walter Klomp wrote:
> Hi Steve, so you are still alive actually :-)
>
> Well, u know what is going to happen there when I complain to them. It
> crashes the actual call, not the complete box obviously. Since a 10 year old
> AS5300 doesn't have any issues talking to this AS5400 and even some third
> party T.38 boxes work flawlessly talking to them, my logical conclusion is
> that somewhere spandsp is still broken. How can we fix this without asking
> the impossible?
>   
Are you having problems with rxfax/txfax talking to this Cisco, or is it 
T.38 gateway operation in Callweaver which causes you trouble? I am 
still working on improving the compatibility of my T.38 gateway 
implementation, but T.38 termination should be pretty reliable now.

Have you tried the latest spandsp snapshot? I think the last time we 
talked was in November, and changes I made in December relax the timing 
of T.38 termination operation. That might be relevant to your problem.

Steve

_______________________________________________
Callweaver-users mailing list
[email protected]
http://lists.callweaver.org/mailman/listinfo/callweaver-users

Reply via email to