Hi Rolando,

This is wrong -- the User IP clock source should be adc0_clk, at 24 MHz.
If you see a design with an ADC, but the clock source is set to to sys_clk,
this is *almost always* a mistake.

Jack

On Sat, 20 Feb 2016 at 19:04 Rolando Paz <flx...@gmail.com> wrote:

> Hi
>
> I have a question about the "User IP clock source" value on the model file
> Leuschner Spectrometer, because this value is programmed as "sys_clk" and
> the ADC has a value "ADC clock rate" of 96MHz.
>
> As I see in Leuschner circuit an external clock is used, then why appears
> sys_clk?
>
> https://casper.berkeley.edu/wiki/Leuschner_Spectrometer
>
> Regards
>
> Rolando Paz
>
>
>

Reply via email to