Actually the original manual set up had a
brass foot on it – holes in that were bigger than the holes in the
electric pump’s grid so hasn’t been an issue so far – but then
I don’t’ get debris in my bilge – I insist people get sick
over the rail not in the cabin <BG> Dave – leeward side please C27 #5212 Windabout http://dpbcc.home.comcast.net From: [email protected]
[mailto:[EMAIL PROTECTED] On
Behalf Of Phil Agur Dave, Hmm… I was going to say you just
can’t mix a centrifugal “Rule” with a diaphragm pump
effectively but, I don’t see much wrong, if anything; with blowing water
through the poppet vales on the manual pump. Maybe you should take an extra precaution
to keep debris from entering the Rule (which doesn’t normally care about
debris) because the manual pump will be quietly disabled if any debris lodges
in the valves while passing through it. Phil Agur
s/v Wing Tip Commodore, Call Sign WCW3485 IC27/270A
www.catalina27.org
Vessel Doc# 1039809 -----Original Message----- Ted – I just attached the electric
bilge pump on the end of the hose in the bilge that goes to the manual pump
– works just fine for me. I can still pump out using the manual
pump and when the electric one runs it just goes through the manual pump. Dave C27 #5212 Windabout http://dpbcc.home.comcast.net From:
[email protected] [mailto:[EMAIL PROTECTED] On Behalf Of ted glynn I'm looking for advice on how to install an automatic
bilge pump on my 82 Catalina 27. I'm still a new sailboater, having had mine
less than 2 years now, so please forgive me if I use the wrong terms or don't
explain it well. My bilge is very dry and clean, but I worry about a
leak when I'm not around, so would like to have the automatic bilge on
"stand by" when I'm gone. I bought a Rule-Mate 500 automated bilge
pump and 3-way lighted panel switch. I think I can figure out the electrical
part ok. My first though was that I could use the same
hose from the bilge that leads to the manual bilge pump in the compartment
aft of the tiller and somehow, via a system of Y or T fittings and check
valves, use the same thru-hull on the transom (which is above the water line).
In other words, both manual and automatic bilge pumps would be operational
(sort of "in parallel"), using largely the same hoses and thru-hull. My first choice would be to run a second hose out the
aft of my bilge, and have a totally redundant hose system, but there doesn't
seem to be much room for it. I also know check-valves can be trouble if they
fail. I've kicked it around with other sailboaters on my
dock without complete agreement on whether it would work, or would one siphon
the other, etc. Any advice, pictures, diagrams, etc. would be
appreciated. Ted Glynn Rayo de Luna 1982 Catalina 27 standard rig |
- RE: catalina27-talk: Installing an automatic bilge pump wh... DaveBreski
- Re: catalina27-talk: Installing an automatic bilge pu... ahoyther
- Re: catalina27-talk: Installing an automatic bilg... Ralph E. Ahseln
- RE: catalina27-talk: Installing an automatic bilg... DaveBreski
- RE: catalina27-talk: Installing an automatic bilge pu... uprr
- RE: catalina27-talk: Installing an automatic bilge pu... uprr
- RE: catalina27-talk: Installing an automatic bilge pu... ted glynn