Hello people from the list. 

I am having and issue connection two 2620's
back-to-back over a serial pipe (DCE-DTE) using either
PPP or HDLC as the encapsulation protocol.

When I connect the two routers using S0/0 on router
"A" and S0/1 on router "B" the connection comes up
with either L2 encap. protocols. I can see each other
through CDP, etc. In this config, I get interface UP
and Line Protocol UP.

When I connect the two routers using the same
interface type/number on both sides (IE S0/1 on router
"A" and S0/1 on router "B"), the connection does not
come up 100%. I see the interface UP but the line
protocol is DOWN on both sides. 

Of course, I am setting the clock rate on the DCE
side, and when I turn on debugging for PPP events, I
see the following:

LCP: Timeout: State ACKsent
LCP: State is Listen

Both routers are 2620's and running IOS 12.3. This is
the config on the interfaces in question:
interface Serial0/1
 no ip address
 encapsulation ppp
 no peer neighbor-route (I can have this command on or
off without difference)

In the Lab that I am currently working on, this is the
physical connection to be used and also I have seen
this same setup on other documents without any
reference to a problem with using the same interface
type/number on both sides. 

If I change the interface on either side (EI S0/0 -
S0/1), the pipe comes up fully.

Does anybody have a clue about this?

Thanks in advanced!



 