Alright, so I'm on my death march through Workbook 3 and I've hit an issue where I had thought I had figured out the problem, my solution didn't work, I checked the DSG, and the exact solution I had tried didn't work.
This is in TS for Lab 3. I' had R6 getting bad neighbor attempts from Area 0 from Router 2. The whole issue boils down to the OSPF network-type being broadcast and inverse arp populating the frame map. OK, so turn off inverse arp and reboot. And then I look again, and somehow it's STILL populating the frame map with the DLCI that gets it to R6. Fine, maybe it's doing the inARP before it gets to the no command? Whatever, I can still beat this thing. Shut down the interface, write mem, reboot. And I'm good. But now R6 is receiving the same bad neighbor attempts from R4. And R4 has "no frame-relay inverse-arp" on its interface. Maybe I missed it before. So I repeat the same process (involving 2 reboots) on R4. ...and now I'm getting the bad neighbor joins from R2 again. And R2 is showing the dynamic map. Exactly what circular hell have I found myself in and what's the cause? _______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com Are you a CCNP or CCIE and looking for a job? Check out www.PlatinumPlacement.com http://onlinestudylist.com/mailman/listinfo/ccie_rs