okay. now that i've refreshed my memory. based on this output by doing
a "sh voice dsp" and doing a "sh diag" I realize that there is no
convention to knowing how channels there are per dsp or how man dsp per
chip. just brute force memorization that a pvdm2-16 is 5510 and that
there are 16 channels though I don't really follow why below is showing
20 channels. so the confusion begins. i suppose it's time to revisit
CCVP material since this is probably something that someone is expected
to know already approaching their lab attempt. either that or it is
non-applicable to getting prepped for the lab. but applicable to the
real world when needing to know how to specify hardware criteria for a
implementation. but by all means, to the folks who can spare the time
and the "expensive lunch", please explain some method to this madness.
-Norm Sandy2811_MPLS_POTS_GW#sh voice dsp
edsp 001 01 g729r8 p 0.1 IDLE 50/0/1.1
edsp 002 01 g729r8 p 0.1 IDLE 50/0/2.1
edsp 003 01 g711ulaw 0.1 IDLE 50/0/3.1
edsp 004 01 g729r8 p 0.1 IDLE 50/0/4.1
edsp 005 01 g729r8 p 0.1 IDLE 50/0/5.1
edsp 006 01 g729r8 p 0.1 IDLE 50/0/6.1
edsp 007 01 g729r8 p 0.1 IDLE 50/0/7.1
edsp 008 01 g729r8 p 0.1 IDLE 50/0/8.1
edsp 009 01 g729r8 p 0.1 IDLE 50/0/9.1
edsp 010 01 g729r8 p 0.1 IDLE 50/0/10.1
edsp 011 01 g729r8 p 0.1 IDLE 50/0/11.1
edsp 012 01 g711ulaw 0.1 IDLE 50/0/12.1
edsp 013 01 g729r8 p 0.1 IDLE 50/0/13.1
edsp 014 01 g729r8 p 0.1 IDLE 50/0/14.1
edsp 015 01 g729r8 p 0.1 IDLE 50/0/15.1
edsp 016 01 g729r8 p 0.1 IDLE 50/0/16.1
edsp 017 01 g729r8 p 0.1 IDLE 50/0/17.1
edsp 018 01 g729r8 p 0.1 IDLE 50/0/18.1
edsp 019 01 g729r8 p 0.1 IDLE 50/0/19.1
edsp 020 01 g729r8 p 0.1 IDLE 50/0/20.1
----------------------------FLEX VOICE CARD 0
------------------------------
*DSP VOICE CHANNELS*CURR STATE : (busy)inuse (b-out)busy out
(bpend)busyout pending
LEGEND : (bad)bad (shut)shutdown (dpend)download pending DSP
DSP DSPWARE CURR BOOT PAK TX/RX
TYPE NUM CH CODEC VERSION STATE STATE RST AI VOICEPORT TS ABRT
PACK COUNT
===== === == ========= ======= ===== ======= === == ========= == ====
============
*DSP SIGNALING CHANNELS*
DSP DSP DSPWARE CURR BOOT PAK
TX/RX
TYPE NUM CH CODEC VERSION STATE STATE RST AI VOICEPORT TS ABRT
PACK COUNT
===== === == ========= ======= ===== ======= === == ========= == ====
============
C5510 001 01 {flex} 8.4.7 alloc idle 0 0 0/1/0 02
0 173/0
C5510 001 02 {flex} 8.4.7 alloc idle 0 0 0/1/1 06
0 86/0
C5510 001 03 {flex} 8.4.7 alloc idle 0 0 0/1/2 10
0 61/0
C5510 001 04 {flex} 8.4.7 alloc idle 0 0 0/1/3 14
0 270/0
------------------------END OF FLEX VOICE CARD 0
----------------------------Sandy2811_MPLS_POTS_GW# It is apparent that
there are 20 dsps so
----- Original Message -----
From: "Norma Exel"
To: "Kevin Porter" , [email protected]
Subject: Re: [OSL | CCIE_Voice] CME Transcoder units and sessions
Date: Sat, 8 Nov 2008 14:12:37 -0500
are we talking 539s or 5510 dsps? read somewhere that 5510 dsps can
be oversubscribed. that is, since oversubscribed may be mistaken as
term loosely used in this case, the 5510 dsp can be allocated to
dspfarm and be used for the voice-port. so when it is not being used
to encode PCM to g711/g729/etc on the voice-port it is available for
transcoding or conference bridge. i believe 539 only have 4 channels
and 5510 have 6 channels. let me do a sh voice dsp or sh dspfarm dsp
all to verify before anybody takes my word for it!>:0o Norm
----- Original Message -----
From: "Kevin Porter"
To: [email protected]
Subject: [OSL | CCIE_Voice] CME Transcoder units and sessions
Date: Thu, 30 Oct 2008 09:58:55 -0500
Question on CME Transcoder values
Is the sdspfarm units <1-5> referring to the number of voice-card
interfaces that would be used for transcoding?
What is the calculation used to determine how many sessions you can
configure for extra DSP channels
Say you have three PVDM-12s and a
four channel PRI in the router
I think I recall hearing from one of the
bootcamps that the Transcoder uses two channels per session? If so,
would the calculation be
36 channels total minus four for the PRI,
leaving 32 and divide by two, resulting in 16 sessions?
Thanks,
Kevin
Kevin Porter
Systems Engineer L4
Netelligent Corporation
400 South Woods Mill Drive, Suite 105
St. Louis, MO 63017
Office: (314) 392-6921
Cell: (314) 852-1252
Fax: (314) 392-9760
[EMAIL PROTECTED]
www.netelligent.com
Bridging The Gap Between Good and GREAT IP Communications!
-- Be Yourself @ mail.com!
Choose From 200+ Email Addresses
Get a Free Account at www.mail.com!
--
Be Yourself @ mail.com!