Hi Roger, I checked the replication on a cli on both, PUB/SUB: admin:show perf query class "Number of Replicates Created and State of Replication" ==>query class :
- Perf class (Number of Replicates Created and State of Replication) has instances and values: ReplicateCount -> Number of Replicates Created = 412 ReplicateCount -> Replicate_State = 2 I know the config is correct, because if I stop Call manager service on the Sub, or remove it from the Call Manager group, everything works fine... So it has to be good. I don't want to loose much time with this, as I'm with proctorlabs online rack rental, so I refer to finish the lab. at the end if I finish it much earlier, then I might do it, and reset the replication between sub/pub. Thanks for anwering Roger! Cheers, On Sun, Mar 27, 2011 at 3:45 PM, Roger Carpio <roger.car...@gmail.com>wrote: > Hello George, > > Very rarely I've seen replication status 2 and weird behaviors happen. Have > you checked replication anywhere else? CLI / Unified Reporting? > > If you've done this many times and you're sure the configuration has been > done correctly; drop this replication and reset it "cluster wide". I hope it > helps. > > Regards, > Roger Carpio. > > On Sun, Mar 27, 2011 at 8:28 AM, George Goglidze <gogli...@gmail.com>wrote: > >> Hi all, >> >> I was wondering if anyone has seen this before. >> >> There is a requirement to show in Missed/Received directory numbers in >> E164 format, but in alerting/connected state it should be localized for >> user. >> Subscriber to 7digit, national to 10digit, international to 011.... >> >> I have configured correct prefixes on the incoming gateways, so >> Missed/Received directory is fine! It shows correct values with the +sign >> E164 format. >> >> And I have configured pt-norm-hq-ani, pt-norm-br1-ani, pt-norm-br2-ani, >> which are in their corresponding css-norm-hq-ani, css-norm-br1-ani, >> css-norm-br2-ani >> and I've applied them to the corresponding Device Pools, in "Calling Party >> Transformation CSS". >> >> But when the call comes in, I still get in alerting/connected state E164 >> format. >> >> All my devices phones and gateways are registered to Sub first, and in >> failed to Publisher. >> >> If I change this and I register all the devices to the Publisher, instead >> of a subscriber, changing it in Callmanager group configuration, then it all >> works as expected. >> Therefore I thought maybe Sub is not replicating correctly, but I've >> checked and the replication Status is 2! which means it's replicating fine. >> I have even restarted the Subscriber but it didn't fix the issue. >> >> I am out of ideas, and I've done it many times in prior Labs, and it has >> always worked fine! >> I've searched through CCM Service Parameters, and couldn't find anything >> that could affect this behaviour. >> >> If anyone has seen this, please let me know... >> >> Regards, >> >> _______________________________________________ >> For more information regarding industry leading CCIE Lab training, please >> visit www.ipexpert.com >> >> >
_______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com