MR may work - it is worth a trial. Are you sure the SG is P622 or could it be P6i 22?

You can check al these with MR and hope to get a much better result in the correct SG
Eleanor

Vandana Kukshal wrote:

hello sir ,

recently i have collected one data of 3.0 A of a
protein having no sequence homology with any known PDB . but while fold prediction i got 100 % identical fold with some of the protein . space group of my protein is P622 and showing 6 molecule in a assymetric unit. the homologous fold proteins are trimer protein. can i run MR in this case . how i should proceed. i m trying for MIR also . regards vandana

Reply via email to