Hi Arpita

You can try QUANTI-iT
Protein assay kit from Invitrogen.

But still there is
nearly 20-50% discrepancy between this method and a Abosorbance at 280.

I also faced same
problem with a protein, then re-cloned by adding a Trp at the C-terminus.

Raj

 
E. Rajakumara
Postdoctoral Fellow  Strcutural Biology Program  Memorial Sloan-Kettering 
Cancer Center  New York-10021  NY  001 212 639 7986 (Lab)  001 917 674 6266 
(Mobile)

--- On Sat, 9/4/11, Arpit Mishra <ar...@igib.in> wrote:

From: Arpit Mishra <ar...@igib.in>
Subject: [ccp4bb] how to quantitate protein which dont have ne aromatic residue
To: CCP4BB@JISCMAIL.AC.UK
Date: Saturday, 9 April, 2011, 3:22 PM

hello everybody
i am working on the protien which dont have any aromatic residue  i do fplc 
other purification using 220 absorption, but i want to quantitate protein 
precisely i have tried using BCA nd bradford but both methods quantification is 
not matching,,so any one is having sum idea how to quantitate it precisely 

thanks in advance for your valuable suggestion..

Arpit Mishra