Dear Anita

You are seeing the effects of a very modest reduction of vapor pressure of 
water with polymers. You could add salt to your reservoir and you could insure 
your drops are at the same temperature as your reservoir - not easy in 
conventional "constant temp" incubators. 

George

Sent via BlackBerry by AT&T

-----Original Message-----
From: anita p <crystals...@gmail.com>
Sender: CCP4 bulletin board <CCP4BB@JISCMAIL.AC.UK>
Date: Fri, 9 Sep 2011 19:22:53 
To: <CCP4BB@JISCMAIL.AC.UK>
Reply-To: anita p <crystals...@gmail.com>
Subject: [ccp4bb] drops swelling

Dear Crystallographers,
I have set hanging drop trays with 2ul of protein and 2 ul of resorvior
solution. I have seen in some cases the drops are swelling. My protein
buffer has 15% glycerol in it.
This is happening mainly when I have peg 400 or peg MME or MPD or Jeffamine
in the buffer condition.
Could any one suggest a remedy for this.

with regards
Anita