Dear ccp4b collective mind and experience,

Greetings from San Diego.

I have done my fair share of synchrotron data collection on many diverse 
macromolecular crystal systems.  But this weekend was the first time that I 
ever shot crystals that failed to diffract entirely.

Details:  we have purified and crystallized an ~90 kDa proteolytic fragment 
containing a single point mutant version of a myosin motor domain in complex 
with a separate light chain polypeptide.  The crystals are relatively small 
(10-30 microns in each dimension) but clearly crystalline in character (clear 
faces, edges, and facets).  The crystals tested positive for protein by 
absorbance at 280 nm.  This weekend we tested more than 40 of them for 
diffraction in different cryo solvents and did not observe a single 
identifiable diffracted ray.  It was as if we had only cryo on the end of our 
loops.  Increasing the time of exposure or annealing did nothing to improve the 
situation.  Crystals from a different protein system that we also tested this 
weekend on the same beamline diffracted to beyond 1.3 Å.

I only post this because, in my experience, crystals of this size and 
superficial quality always give some signal--even if it is horrifyingly bad.  
But never complete diffraction silence.  We will work this week to identify 
what it is that we "crystallized".  But can anybody who has had a similar 
experience suggest what it is that could be going on here?

Thanks in advance for any responses.  And happy holidays to us all.

Tom Huxford.
======================
Tom Huxford.
Structural Biochemistry Laboratory
Department of Chemistry & Biochemistry
San Diego State University
(619) 594-1606

Reply via email to