On Fri, Sep 17, 2021 at 8:54 AM Eric Dold <dold.e...@gmail.com> wrote:
>
> Hi,
>
> I get the same after upgrading to 16.2.6. All mds daemons are standby.
>
> After setting
> ceph fs set cephfs max_mds 1
> ceph fs set cephfs allow_standby_replay false
> the mds still wants to be standby.
>
> 2021-09-17T14:40:59.371+0200 7f810a58f600  0 ceph version 16.2.6
> (ee28fb57e47e9f88813e24bbf4c14496ca299d31) pacific (stable), process
> ceph-mds, pid 7113
> 2021-09-17T14:40:59.371+0200 7f810a58f600  1 main not setting numa affinity
> 2021-09-17T14:40:59.371+0200 7f810a58f600  0 pidfile_write: ignore empty
> --pid-file
> 2021-09-17T14:40:59.375+0200 7f8105cf1700  1 mds.ceph3 Updating MDS map to
> version 226251 from mon.0
> 2021-09-17T14:41:00.455+0200 7f8105cf1700  1 mds.ceph3 Updating MDS map to
> version 226252 from mon.0
> 2021-09-17T14:41:00.455+0200 7f8105cf1700  1 mds.ceph3 Monitors have
> assigned me to become a standby.
>
> setting add_incompat 1 does also not work:
> # ceph fs compat cephfs add_incompat 1
> Error EINVAL: adding a feature requires a feature string
>
> Any ideas?

Please share `ceph fs dump`.


-- 
Patrick Donnelly, Ph.D.
He / Him / His
Principal Software Engineer
Red Hat Sunnyvale, CA
GPG: 19F28A586F808C2402351B93C3301A3E258DD79D

_______________________________________________
ceph-users mailing list -- ceph-users@ceph.io
To unsubscribe send an email to ceph-users-le...@ceph.io

Reply via email to