You have of course been deleting and re-creating the APPLICATION.userGateway object after you've been making these changes, right?
On Tue, Mar 4, 2008 at 10:59 PM, Greg Morphis <[EMAIL PROTECTED]> wrote: > Naaa.. I mean we do have an error template but it normally fires with errors.. > If I misspell something on a .cfm page, it displays all the error info. > I've just noticed that when there's something wrong within a CFC it just > stops.. > > For example if I have a > <cfoutput>#session.user.emplid#</cfoutput> > > <cfset qGroupsX = application.userGateway.getGroupsForUser(emplid = > '0012345')> <!--- error in here somewhere ---> > > <cfdump var="#application#" /> > > The output gets displays but no dump.. > > I have a login page that created the application.userGateway so it > could check security because the onApplicationStart in the .cfc > doesn't seem to fire before the login (not sure why). Anyways.. I > wonder if that was causing the error.. I wrapped it in a > <cfif structkeyexists(application,"userGateway")> > ... create the application.userGateway > </cfif> > > But I want to test... could 2 creates cause the problem? I would > really like some better error messages instead of CF just stopping > (only happens in errors within the CFC) what it's doing... > > > > > > > On Tue, Mar 4, 2008 at 3:31 AM, Tom Chiverton > <[EMAIL PROTECTED]> wrote: > > On Monday 03 Mar 2008, Greg Morphis wrote: > > > No, no aborts.. and yeah.. it returns something.. > > > Something's wrong because like I said CF stops processing.. > > > > Do you have a per-application or server wide exception handler that could > be > > swallowing the error it looks like it must be throwing ? > > > > -- > > Tom Chiverton > > Helping to authoritatively conquer guinine m-commerce > > on: http://thefalken.livejournal.com > > > > **************************************************** > > > > This email is sent for and on behalf of Halliwells LLP. > > > > Halliwells LLP is a limited liability partnership registered in England > and Wales under registered number OC307980 whose registered office address is > at Halliwells LLP, 3 Hardman Square, Spinningfields, Manchester, M3 3EB. A > list of members is available for inspection at the registered office. Any > reference to a partner in relation to Halliwells LLP means a member of > Halliwells LLP. Regulated by The Solicitors Regulation Authority. > > > > CONFIDENTIALITY > > > > This email is intended only for the use of the addressee named above and > may be confidential or legally privileged. If you are not the addressee you > must not read it and must not use any information contained in nor copy it > nor inform any person other than Halliwells LLP or the addressee of its > existence or contents. If you have received this email in error please > delete it and notify Halliwells LLP IT Department on 0870 365 2500. > > > > For more information about Halliwells LLP visit www.halliwells.com. > > > > > > ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~| Adobe® ColdFusion® 8 software 8 is the most important and dramatic release to date Get the Free Trial http://ad.doubleclick.net/clk;160198600;22374440;w Archive: http://www.houseoffusion.com/groups/CF-Talk/message.cfm/messageid:300393 Subscription: http://www.houseoffusion.com/groups/CF-Talk/subscribe.cfm Unsubscribe: http://www.houseoffusion.com/cf_lists/unsubscribe.cfm?user=89.70.4