Alex,

You don't get around it on the 2924. You will need to upgrade to the 2950G-24-EI.

They're not much more than the 2924.

Good luck.

Alex Balashov wrote:
For some reason, my Catalyst 2900 series (WS-C2924-XL) does not like VLAN IDs higher than 1005:


sw01(config)#switchport trunk allowed vlan add 1202
Command rejected: Bad VLAN list - character #5 (EOL) delimits a VLAN
number (1202) out of the range 1 to 1005.

This is with a trunking interface:

interface FastEthernet0/1
 duplex full
 speed 100
 switchport trunk encapsulation dot1q
 switchport trunk allowed vlan 1,3,100,1002-1005
 switchport mode trunk

IOS is 12.0(5)WC8 (C2900XL-C3H2S-M).

I'm pretty sure this has already been asked a thousand times, but how do I get around this issue so I can get support for the extended VLAN IDs up to 4096?

_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to