On Mon, 13 Jan 2020 at 13:07, Harivishnu Abhilash
<[email protected]> wrote:

> You recon, this can be an issue only if > 1 Spoke in SAME PE. ?  In my case, 
> spokes will be in different PE. Also HUB sites won't be having any Spoke VRF.

Then you can get away from using half-duplex VRF and do it the
simple/easy way. But in many cases these tend to change over time, and
if you later get 2nd spoke in any given PE, you're going to have an
issue. At least communicate this limitation clearly to your PM and
such that once the shit hits the fan, you can show that the limitation
was communicated.

-- 