> I need to configure a multichannel E1 8 port adapter
> on cisco7513,is the following correct?
>
> controller E1 1/0/3
> framing no-crc4
> linecode hdb3
> clocksource line
> channel-group 0 timeslots 1-31
> !
> interface serial1/0/3:0
> description to BIEJIE r-7507-bj
> ip address 202.98.208.133 255.255.255.252
> bandwidth 2048
Looks good.
> Must I use the "controller E1" command?Can I use "interface
> serial10/3" directly ? thanks
Nope. The controller configuration sets up the basic parameters of the
physical interface/CSU-DSU, and instantiates the serial interface. The
serial interface doesn't exist until the controller is configured.
Ben
___________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]