>                 I need to configure a multichannel E1 8 port adapter
> on cisco7513,is the following correct?
>                
>       controller E1 1/0/3
>       framing no-crc4
>       linecode hdb3
>       clocksource line
>       channel-group 0 timeslots 1-31
>       !
>       interface serial1/0/3:0
>       description to BIEJIE r-7507-bj
>       ip address 202.98.208.133 255.255.255.252
>       bandwidth 2048

Looks good.

>       Must I use the "controller E1" command?Can I use "interface
> serial10/3" directly ? thanks

Nope.  The controller configuration sets up the basic parameters of the
physical interface/CSU-DSU, and instantiates the serial interface.  The
serial interface doesn't exist until the controller is configured.