The line protocol down means that the other end are not sending keepalives .
So yes its datalink (correct me if I am wrong ).
If you are using back to back is there clocking on your dce side ( do a show
control serial 0 )
look for dce .
If not check that your NTU (clocking device is plugged in)
See that your addressing is correct on both sides .

So in short you should have a dce---dte scene
and there should be clocking on the dce side.
and make sure your addressing is ok !

Hope it helps !
Cheers
Olden


-----Original Message-----
From: Omer Shommo [mailto:[EMAIL PROTECTED]]
Sent: Friday, June 23, 2000 8:00 AM
To: Cisco Group Study
Subject: Serial0 is up, line protocol is down!


Hello to All,

If Serial0 is up, line protocol is down, then what should I check? Give me
as many answers as you can.

BTW what  is the line protocol? is it a network protocol like ip, ipx? or is
it the data link layer protocol?

Omer


_______________________________________________
Why pay for something you could get for free?
NetZero provides FREE Internet Access and Email
http://www.netzero.net/download/index.html

___________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

___________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to