Inverse arp maps layer 3 addresses to the appropriate DLCI.

Yes you can have multiple frame-relay route statements on the same
interface.

Can you tell me which DLCIs you want to announce and on which interface. As
far as i can understand you want to announce DLCI 16 on serial0 and DLCI 18
on serial1. Correct me if i am wrong .

Regards
Atif

-----Original Message-----
From: Olden Pieterse [mailto:[EMAIL PROTECTED]]
Sent: Wednesday, July 05, 2000 2:14 PM
To: 'Atif Awan'
Cc: '[EMAIL PROTECTED]'
Subject: RE: Frame Relay Switching


Hi there
Thx Atif
Its me and my Motorolas again !
We need both 16 & 18 to be switched through serial 0
I left 16 out because I reckoned the inverse arping will take care of that
to create the pvc map .
Is it possible to make multiple statements on a single physical interface ?

Thx in advance
Cheers
Olden

-----Original Message-----
From: Atif Awan [mailto:[EMAIL PROTECTED]]
Sent: Wednesday, July 05, 2000 11:10 AM
To: Olden Pieterse; [EMAIL PROTECTED]
Subject: RE: Frame Relay Switching



it should be like this

Interface serial 0
Frame-relay route 16 interface serial 1 18

Interface serial1
Frame-relay route 18 interface serial 0 16

provided you want to announce DLCI 16 on serial 0 and DLCI 18 on serial 1
and interconnect them to form a PVC ...
I am not getting why you have also written 18 on serial 0 ??

Regards
Atif

-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of
Olden Pieterse
Sent: Wednesday, July 05, 2000 1:30 PM
To: '[EMAIL PROTECTED]'
Subject: Frame Relay Switching


Hi there gang
Is my assumption right concerning this frame relay switching scenario ?



                                Cisco DLCI 16
                             Ser0|       |Ser1
                                |       |
                ------------------------|       |-----------------------
                DLCI 16                                DLCI 18
                DLCI 18

Interface serial 0
Frame-relay route 18 interface serial 1 16

Interface serial1
Frame-relay route 18 interface serial 0 16

Thx






                          Olden Pieterse
               MCP , CCNA , BCMSN , BSCN , BCRAN
Brainbench Certified CISCO Network Implementation Specialist
                      Technical Consultant
Mobile : +27 82 410 8621

___________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

___________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to