It should work like a charm.  I have noticed that the back to back
serial cables (1 cable instead of 2 separate DTE/DCE cables) seem to be
very shaky  (out of the 15-20 back to back cables at least 3 have been
unable to reliably setup a serial connection).......

Andre'

-----Original Message-----
From: Vic Dmon [mailto:[EMAIL PROTECTED] 
Sent: Monday, July 28, 2003 5:22 PM
To: [EMAIL PROTECTED]
Subject: NP-2T to 2500 [7:73127]


Hi, has anyone had any problems with connceting a NP-2T serial interface
to a 2500 serial interface. I ordered a cable with the DB60 end being
the DTE and the DB50 (NP-2T) being the DCE. I have put the clockrate
command on the DCE end but cannot get the interface to come up. I tried
different clock rate settings also. I understand that this may be a
problem with the jumper settings on the 4000 but I just want to confirm
if anyone has ever come across this issue. Appreciate the help.

2500 show controller output:

HD unit 0, idb = 0x250D1C, driver structure at 0x258730
buffer size 1524  HD unit 0, RS-449 DTE cable
cpb = 0xE2, eda = 0x2940, cda = 0x2800
RX ring with 16 entries at 0xE22800
00 bd_ptr=0x2800 pak=0x256354 ds=0xE26108 status=80 pak_size=0 01
bd_ptr=0x2814 pak=0x256620 ds=0xE267C4 status=80 pak_size=0 02
bd_ptr=0x2828 pak=0x2568EC ds=0xE26E80 status=80 pak_size=0 03
bd_ptr=0x283C pak=0x256BB8 ds=0xE2753C status=80 pak_size=0 04
bd_ptr=0x2850 pak=0x256E84 ds=0xE27BF8 status=80 pak_size=0 05
bd_ptr=0x2864 pak=0x257150 ds=0xE282B4 status=80 pak_size=0 06
bd_ptr=0x2878 pak=0x25741C ds=0xE28970 status=80 pak_size=0 07
bd_ptr=0x288C pak=0x2576E8 ds=0xE2902C status=80 pak_size=0 08
bd_ptr=0x28A0 pak=0x2579B4 ds=0xE296E8 status=80 pak_size=0 09
bd_ptr=0x28B4 pak=0x257C80 ds=0xE29DA4 status=80 pak_size=0 10
bd_ptr=0x28C8 pak=0x257F4C ds=0xE2A460 status=80 pak_size=0 11
bd_ptr=0x28DC pak=0x258218 ds=0xE2AB1C status=80 pak_size=0 12
bd_ptr=0x28F0 pak=0x258994 ds=0xE2B1D8 status=80 pak_size=0 13
bd_ptr=0x2904 pak=0x258C60 ds=0xE2B894 status=80 pak_size=0 14
bd_ptr=0x2918 pak=0x258F2C ds=0xE2BF50 status=80 pak_size=0 15
bd_ptr=0x292C pak=0x2591F8 ds=0xE2C60C status=80 pak_size=0 16
bd_ptr=0x2940 pak=0x2594C4 ds=0xE2CCC8 status=80 pak_size=0 cpb = 0xE2,
eda = 0x3000, cda = 0x3000 TX ring with 4 entries at 0xE23000

----------------------------------------------------------------

4000 NP-2T show controller output:

MK5 unit 1, NIM slot 2, NIM type code 7, NIM version 1
idb = 0x69E8, driver structure at 0xE6EFB8, regaddr = 0x8200400 IB at
0x603D640: mode=0x0108, local_addr=0, remote_addr=0 N1=1524, N2=1,
scaler=100, T1=1000, T3=2000, TP=1 buffer size 1524 DCE V.11 (RS-449 or
X.21) serial cable attached, clockrate 56000 RX ring with 32 entries at
0x3D6A8 : RLEN=5, Rxhead 0 00 pak=0xE7228C  ds=0x6046264 status=80
max_size=1524 pak_size=0 01 pak=0xE70FEC  ds=0x6042C84 status=80
max_size=1524 pak_size=0 02 pak=0xE732D8  ds=0x6049188 status=80
max_size=1524 pak_size=0 03 pak=0xE71494  ds=0x60439FC status=80
max_size=1524 pak_size=0 04 pak=0xE716E8  ds=0x60440B8 status=80
max_size=1524 pak_size=0 05 pak=0xE73780  ds=0x6049F00 status=80
max_size=1524 pak_size=0 06 pak=0xE71240  ds=0x6043340 status=80
max_size=1524 pak_size=0 07 pak=0xE7193C  ds=0x6044774 status=80
max_size=1524 pak_size=0 08 pak=0xE71B90  ds=0x6044E30 status=80
max_size=1524 pak_size=0 09 pak=0xE72038  ds=0x6045BA8 status=80
max_size=1524 pak_size=0 10 pak=0xE72734  ds=0x6046FDC status=80
max_size=1524 pak_size=0 11 pak=0xE72988  ds=0x6047698 status=80
max_size=1524 pak_size=0 12 pak=0xE72BDC  ds=0x6047D54 status=80
max_size=1524 pak_size=0 13 pak=0xE73084  ds=0x6048ACC status=80
max_size=1524 pak_size=0 14 pak=0xE7352C  ds=0x6049844 status=80
max_size=1524 pak_size=0 15 pak=0xE739D4  ds=0x604A5BC status=80
max_size=1524 pak_size=0
For more information about Barclays Capital, please
visit our web site at http://www.barcap.com.


Internet communications are not secure and therefore the Barclays 
Group does not accept legal responsibility for the contents of this 
message.  Although the Barclays Group operates anti-virus programmes, 
it does not accept responsibility for any damage whatsoever that is 
caused by viruses being passed.  Any views or opinions presented are 
solely those of the author and do not necessarily represent those of the 
Barclays Group.  Replies to this email may be monitored by the Barclays 
Group for operational or business reasons.

------------------------------------------------------------------------




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=73132&t=73127
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to