>>>> David Vital 8/1/03 8:04:21 AM >>> >I have to ask what you are basing that statement on. I'm not trying to >dispute you, just to gain moe information. I have never seen anything that >would indicate a change in Duplex when set to 100 full on each end. Are you >suggesting that 100/half is the way to go with this? > >David
Yes, that's what I'm saying. It's difficult to find this information but I was able to find it at one time and it's been proving out experientially in our network. We tend to buy a lot of one particular major computer manufacturer, and the NICs they use will do this. In fact, most of the NICs on our newer computers behave this way. It's almost a weekly issue around here since we started rolling out newer Cisco switches. It was not a problem with the 2924XL and Cat 5000, but it became a huge problem when we upgraded to a 6500, 2948G, 2980G, and 2950s. I'll look around to see if I can find those references for you and I'll post them if I'm successful. John Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=73345&t=73195 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]