In dutch, to keep things easy.
Denk dat je eerst even de zaken moet proberen.
controle kabel
checken met commando sh controller serial, zie je een interface type staan,
dus die dce/dte
sh interface serial x
Router# show interfaces serial
Serial 0 is up, line protocol is up
Hardware is MCI Serial
Internet address is 131.136.190.203, subnet mask is 255.255.255.0
MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec, rely 255/255, load 1/255
Encapsulation HDLC, loopback not set, keepalive set (10 sec)
Last input 0:00:07, output 0:00:00, output hang never
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
Five minute input rate 0 bits/sec, 0 packets/sec
Five minute output rate 0 bits/sec, 0 packets/sec
16263 packets input, 1347238 bytes, 0 no buffer
Received 13983 broadcasts, 0 runts, 0 giants
2 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 2 abort
1 carrier transitions
22146 packets output, 2383680 bytes, 0 underruns
0 output errors, 0 collisions, 2 interface resets, 0 restarts check onderaan
dte/dce/rts/cts signalen moeten werken
configuratie
standaard configuratie
de ene is dce (moet commando clockrate bv 64000 bij)
ander is dte geen clockrate
Martijn
-----Oorspronkelijk bericht-----
Van: LINSEN Jurgen (BMB) [mailto:[EMAIL PROTECTED]
Verzonden: vrijdag 8 augustus 2003 9:37
Aan: [EMAIL PROTECTED]
Onderwerp: RE: cisco back to back cable [7:71992]
Sure you're using a cross cable?
-----Original Message-----
From: KW S [mailto:[EMAIL PROTECTED]
Sent: Monday, July 07, 2003 6:22 PM
To: [EMAIL PROTECTED]
Subject: cisco back to back cable [7:71992]
Dear All
I have a 2501 and 2505 and I am trying to set up a homelab..These 2
routers come with a cable which is a DB60(DTE) and the other end is a
DB60(DCE).This is wat that is label on the cable. Anyway, I try to
connect this cable to the serial interface of the 2 routers...and both
the routers are showing serial is down and line protocol is down.
I guess I have used the wrong cable...or maybe I have missed out
something.
Please comment..
Regards, kws
**** DISCLAIMER ****
"This e-mail and any attachment thereto may contain information which is
confidential and/or protected by intellectual property rights and are
intended for the sole use of the recipient(s) named above.
Any use of the information contained herein (including, but not limited to,
total or partial reproduction, communication or distribution in any form) by
other persons than the designated recipient(s) is prohibited.
If you have received this e-mail in error, please notify the sender either
by telephone or by e-mail and delete the material from any computer".
Thank you for your cooperation.
For further information about Proximus mobile phone services please see our
website at http://www.proximus.be or refer to any Proximus agent.
**Please support GroupStudy by purchasing from the GroupStudy Store:
http://shop.groupstudy.com
FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=73713&t=71992
--------------------------------------------------
**Please support GroupStudy by purchasing from the GroupStudy Store:
http://shop.groupstudy.com
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html