Yes you can do HSRP between 2 MSFC's in the same box.

On Sat, 19 Aug 2000, Mike Davis wrote:

> All,
> I am new to the 3layer switchs. We will be installing
> a cat 6009 with MSFC, & a redundant sup1a.
> 
> I want to configure HSRP and/or load balancing. So my
> question is can you configure HSRP with interface
> Vlans based on the 2 sups? Between the reg sup and
> redundant sup.
> Where one is configured with odd vlans and the
> redundant with even vlans. Like how you would do it
> with 2 physical separate 6009 cat devices?
> 
> I have not really worked with any of the above
> concepts. I have searched and read many books and
> white papers but have not really found a solid answer
> on this one. I understand you can do it between 2
> separate devices such as routers and switches.
> Is this possible between sups in the same device?
> 
> Thank you for feedback!
> 
> 
> __________________________________________________
> Do You Yahoo!?
> Yahoo! Mail – Free email you can access from anywhere!
> http://mail.yahoo.com/
> 
> ___________________________________
> UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
> FAQ, list archives, and subscription info: http://www.groupstudy.com
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
> 

-----------------------------------------------
Brian Feeny, CCNA, CCDA       [EMAIL PROTECTED]   
Network Administrator         
ShreveNet Inc. (ASN 11881)            

___________________________________
UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
FAQ, list archives, and subscription info: http://www.groupstudy.com
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]