I assume you've tried different ports and different cables
 
If it's a real IBM mau you may have to reinitialize the port.  there is a battery powered tool that used to come with the mau.  It also could be a speed mismatch if the mau has a way to set the ring speed.  There used to be 4mbps only media filters (back in the day) if you are using one of those on a 16mbps ring, weird things can happen.
 
daveh
-----Original Message-----
From: Circusnuts [mailto:[EMAIL PROTECTED]]
Sent: Sunday, September 17, 2000 6:05 AM
To: [EMAIL PROTECTED]
Subject: MAU trouble shooting

Does this mean my MAU is fried ???  It has never come off initializing (left the routers run connected all night)...
 
 
TokenRing0 is initializing, line protocol is down
  Hardware is TMS380, address is 0000.30c0.ec2a (bia 0000.30c0.ec2a)
  Internet address is 195.5.5.10/24
  MTU 4464 bytes, BW 16000 Kbit, DLY 630 usec, rely 255/255, load 1/255
  Encapsulation SNAP, loopback not set, keepalive set (10 sec)
  ARP type: SNAP, ARP Timeout 04:00:00
  Ring speed: 16 Mbps
  Single ring node, Transparent Bridge capable
  Source bridging enabled, srn 49904 bn 0 trn 49904
    proxy explorers disabled, spanning explorer disabled, NetBIOS cache disable
 
Thanks !!!
Phil