Are you using a T-1 x-over cable to connect the 2 T-1 cards?
You need a cable with pins 1-2 crossed to pins 4-5, pins 4-5 corssed to pins
1-2...
Are the line coding settings the same on each?





-----Original Message-----
From: Sampy Ren [mailto:[EMAIL PROTECTED]]
Sent: Wednesday, January 17, 2001 8:23 AM
To: [EMAIL PROTECTED]
Subject: Connecting 3640s


I am trying to connect two 3640's back to back through
their WIC1-DSU-T1 cards.  On one iam defining Clcok
source internal and in the other clock source line. 
the status is up down.  Encapsulation : HDLC.

Any idea what could be the problem?