Can do. Make up a cable swapping pins 1&2 with 7&8 and 7&8 with 1&2. Need to
add clocking one end. Ask others for the exact command.

> -----Original Message-----
> From: Bob Timmons [mailto:[EMAIL PROTECTED]]
> Sent: Monday, February 12, 2001 12:09 PM
> To: [EMAIL PROTECTED]
> Subject: Connecting 2 routers via 56K CSU/DSU's?
> 
> 
> All,
> 
> Does anyone know if I can connect my 2-2524's via their 4-wire 56K
> CSU/DSU's?  I know I can connect them via the 5-in-1 modules 
> with a DB60
> back-to-back cable, but I don't know if a 56K will connect to 
> another 56K
> module.
> 
> Thanks,
> Bob
> 
> 
> _________________________________
> FAQ, list archives, and subscription info: 
> http://www.groupstudy.com/list/cisco.html
> Report misconduct 
> and Nondisclosure violations to [EMAIL PROTECTED]
> 

_________________________________
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]