Make sure you're using the correct encapsulation on the serial interface.
Also it wouldn't hurt to check the frame relay encap type and lmi type.
these should match your ISP's setting on their switch.

--
Joe N., CCNA
Teligent NOC Data Engineer 1



""Thomas"" <[EMAIL PROTECTED]> wrote in message
96qjjv$94a$[EMAIL PROTECTED]">news:96qjjv$94a$[EMAIL PROTECTED]...
> Hi All - I am bringing up a frame circuit from a remote site.  However, I
> couldn't get the line up since it is looped.  When I do the "show int
s0/0",
> I got "Protocol is up, line is down (looped).  I checked all the setting
and
> didn't see any wrong.  Can this be a mistake on the ISP side, or something
> wrong with my configuration? I am running 12.1 on the Cisco 2600 router.
> Any hint woule be appreciated!!!
>
>
> _________________________________
> FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
>


_________________________________