Hello all,
    I am having a problem with a WIC-2T. The setup is as follows: A pair of
HDSLs connected back-to-back. The clock is generated from one of the units
internally, and the other unit receives this clock and uses it. When I
connect a normal serial at one end to a smart serial on the other, I get a
lot of errors on the serial interface in the frame counter. However when I
connect normal serial at both ends, everything works fine... Do I have to
put a certain commend on either interfaces to work....  On the other hand
the same card WIC-2T is working fine with a 128k circuit using NTUs
connected to a TDM MUX, with normal serial on the other end also....
Regards,
-------------------------------------------------
Hossam El-Ashkar
[EMAIL PROTECTED]