Yes- the AGS+ V.35 (Winchester) interfaces can be set to DCE.  You must make
the change on the Serial card.  The cable you need is a crossover DTE to DCE
pin.  The traditional DTE/ CSU cable will not work.  I haven't ordered these
cables before, but I have gotten quotes from Dave @
http://pacificcable.com/CiscoCables.htm.  I believe the cost is around $50 &
he did not have them pre-made.

Good Luck !!!
Phil

----- Original Message -----
From: nathan cruz 
To: 
Sent: Sunday, May 20, 2001 9:13 PM
Subject: AGS+ V.35 34 PIN Applique can it be DCE?? [7:5203]


> Group,
>
> Looked in the archives about setting the serial cables to DCE. I've set
the
> jumpers on the MCI card to 41 and 51. I also experimented with taking the
one
> jumper on the applique off but I still can't seem to get it to pick up the
> DCE
> side.
>
> So I have two questions?
>
> 1. Can the older V.35 34 pin applique be set to DCE?
>
> 2. Can I use the CAB-v35mt cable which would usually be plugged from a dsu
to
> the hd60 on the 2500.
> Or is there a difference in the pin outs?
>
> Thanks in advance for all advice.
>
> Nathan