the ags+ or CGS is doing clocking, I forgot to list the command in my
email.

I just tryed something else. I plugged a standard 2500 V35 DTE cable to
the CAB-VCF and connected the ags+ to a 2501. The interfaces came up/up
and stayed that way.

I may have 2 bad CAB-SS-V35MT's, or a bad port on the WIC-2T.

tim


Tim Medley - CCNP+Voice
Network Architect
VoIP Group
iReadyWorld

704-943-3615 - Phone
704-943-3660 - Fax
877-6-iReady - Helpdesk



-----Original Message-----
From: Jim Brown [mailto:[EMAIL PROTECTED]]
Sent: Tuesday, July 03, 2001 10:44 AM
To: Tim Medley; [EMAIL PROTECTED]
Subject: RE: AGS+ crossed over to 2610, Serial cable length issue?
[7:10810]


Which interface is providing clock for the connection? I don't see a
'clock
rate XXXXX" command under either interface?

-----Original Message-----
From: Tim Medley [mailto:[EMAIL PROTECTED]]
Sent: Tuesday, July 03, 2001 8:51 AM
To: [EMAIL PROTECTED]
Subject: AGS+ crossed over to 2610, Serial cable length issue? [7:10810]


I've finally decided to sit down and try to troubleshoot what I thought
was a faulty serial port on my AGS+.

I have a 2610 with a WIC-2T connected to my AGS+ via a CAB-SS-V35MT and
a CAB-VCF. The CAB-VCF is from pacific cables and is a 26pin DCE to a
V.35 winchester cable. The CAB-VCF is 6 feet long and the CAB-SS-V35MT
is 10 feet long; so I have a 16 foot crosover cable.

When I cable the two routers together and just configure a simple point
to point connection, with the following config:

AGS+
int s2
ip address 100.100.100.1 255.255.255.252
encap ppp
no shut

2610
int s0/0
ip address 100.100.100.2 255.255.255.252
encap ppp
no shut

The serial interfacces come up/up but then after a second or two line
protocol goes down on both sides and they become up/down.

I thought the AGS+'s serial interface was bad (I had a bad applique a
while back). So I moved to a different interface on the AGS+, same
situation.

I then decided to try a different router, I replaced the AGS+ with a
CGS, and I got the same results.

I now think the issue is with the cable. a) I could have a bad cable. b)
the cable I have could be two long.  I have replaced the CAB-SS-V35MT,
with no luck. What kind of issues would I see if the cable was too long?
Would I see the issue I am experiencing? I'm getting ready to call
Pacific Cable and order another CAB-VCF.

tim




Tim Medley - CCNP+Voice
Network Architect
VoIP Group
iReadyWorld

704-943-3615 - Phone
704-943-3660 - Fax
877-6-iReady - Helpdesk




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=10815&t=10815
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to