Jay,  The telco can loop your CSU/DSU either internal or external.  They can
only loop the CSU portion of your CSU/DSU.  Their is a loop up command for
the CSU and another command for the NIE (for 56K/64K circuits)/NIU(for full
T1's) or smart jack whichever you prefer.  

-----Original Message-----
From: Jay Creasy [mailto:[EMAIL PROTECTED]]
Sent: Thursday, November 01, 2001 2:42 PM
To: [EMAIL PROTECTED]
Subject: telco looping [7:24972]


When troubleshooting a typical T1 with telco and they say they have
your CSU looped. Are they actually able to give the CSU inside the Cisco
Router a command to be looped or are they really just looping the
smart-jack/demark ? I've been on the phone with telco and seen that when
they claim to have the CSU\DSU looped, what they are actually doing is
looping the smart-jack/demark, which will loop all traffic from the csu
back on itself.


Jay 