Pierre,

Hi!  You have the wrong switch type configured for the Simline2.  You want:

ISDN switch-type basic-net3

Also, this switch type does NOT use spids!  FYI

thanks,
-Brad Ellis
CCIE#5796 (R&S / Security)
Network Learning Inc
[EMAIL PROTECTED]
used Cisco gear:  www.optsys.net
CCIE Labs, racks, and classes:  http://www.ccbootcamp.com/quicklinks.html

""Pierre-Alex J. Guanel""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> I am using the Slimline 2 ISDN simulator from PDS technologies.
>
> I cannot get the SPID to be accepted. (See below)
>
>
> ISDN BRI0 interface
>         dsl 0, interface ISDN Switchtype = basic-5ess
>     Layer 1 Status:
>         ACTIVE
>     Layer 2 Status:
>         TEI = 64, Ces = 1, SAPI = 0, State = MULTIPLE_FRAME_ESTABLISHE
>         TEI 64, ces = 1, state = 4(await init)
>             spid1 configured, no LDN, spid1 sent, spid1 NOT valid
>
> I have not modifed the default phone numbers 1111 and 2222 configured on
> Slimline
>
> Below are my configs for bri0
> interface BRI0
>  ip address 10.0.0.1 255.255.255.0
>  encapsulation ppp
>  no ip route-cache
>  no ip mroute-cache
>  dialer map ip 10.0.0.2 1111
>  dialer-group 1
>  isdn switch-type basic-5ess
>  isdn spid1 2222
>
> Is there a default LDN number I have to configure?
>
> Pierre-Alex




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=27369&t=27365
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to