Patrick Donlon wrote:

> Positive, if you look at the show port (on the other mail) you'll see there
> are no collisions

As the port is in full duplex, the fact that it doesn't show any
collisions doesn't mean anything, as it doesn't look for them. I agree
with the previous poster: triple-check the NIC in the RS6000. Lots of
runts, CRC errors and alignment errors on a FDX port is an almost-sure
sign that the other end is set to half duplex.

                Regards,

                        Marco.