Hello All ,

Secenario:
Channelized E1 card on 3600 series router connected to Mux  at Telco end .

Observations:
When the E1 is completely looped the Telco gets the loop very fine on the
BERT meter .No slips , No errors

Problem:
When any of the individual timeslots on the E1 is looped then the Telco gets
slip error on the BERT meter .Due to this any of the 64K circuits configured
on any of the timeslots gets at least 2 ping timeouts out of every 1000 ping
packets when any of the timeslot is looped from the Cisco or Telco end.

Solution tried:
1) Changed the clock source from internal/external on the channelized E1
card but the problem remains the same.
2) Changed 02 cards at TELCO end , problem remains the same .

Cisco WAN champions pls let me have your feedback on the above problem so as
to resolve it.

Thanks in advance.
Vijendra.