The MIDI file parser misinterprets events without status byte when they appear directly after a Meta of SysEx event.
For my bugfix I had to decide between two possible solutions: - Strict solution: Throw an InvalidMidiDataException - Tolerant solution: Use the status of the last channel event as running status I used the tolerant solution. I will send an email to the list client-libs-dev with my reasons. ------------- Commit messages: - 8319598: Fixed incorrect interpretation of interrupted running status in SMFParser Changes: https://git.openjdk.org/jdk/pull/16546/files Webrev: https://webrevs.openjdk.org/?repo=jdk&pr=16546&range=00 Issue: https://bugs.openjdk.org/browse/JDK-8319598 Stats: 121 lines in 2 files changed: 118 ins; 0 del; 3 mod Patch: https://git.openjdk.org/jdk/pull/16546.diff Fetch: git fetch https://git.openjdk.org/jdk.git pull/16546/head:pull/16546 PR: https://git.openjdk.org/jdk/pull/16546