FTS18 opened a new pull request, #66230:
URL: https://github.com/apache/airflow/pull/66230

   This PR fixes a critical crash in the scheduler (and other components) where 
`PercentFormatRender` would raise a `TypeError` when a numeric log format 
specifier (like `%d`) was used for callsite parameters (`process`, `thread`, 
`lineno`) that were missing or unknown.
   
   ### Problem
   As reported in #66195, during startup, certain warnings (like insecure key 
length) are emitted before the full logging context or `CallsiteParameterAdder` 
has had a chance to populate the event dictionary. In these cases, our internal 
`_LazyLogRecordDict` would return `None` or the string `"(unknown)"`. If the 
configured `log_format` uses `%d` for these fields, Python's string 
interpolation fails:
   `TypeError: %d format: a real number is required, not str`
   
   ### Solution
   Updated `_LazyLogRecordDict.__getitem__` in 
`shared/logging/src/airflow_shared/logging/percent_formatter.py` to explicitly 
handle `lineno`, `thread`, and `process`. It now returns `0` if the value is 
missing or equal to the `"(unknown)"` placeholder string.
   
   ### Changes
   - **Fix**: Logic added to `percent_formatter.py` to provide safe numeric 
defaults.
   - **Test**: Added `shared/logging/tests/logging/test_issue_66195.py` as a 
regression test.
   - **Newsfragment**: Added bugfix newsfragment.
   
   closes: #66195 


-- 