   Thanks for the detailed report and the reproducible steps. The analysis 
makes sense: the type name for the added column comes from Debezium's 
`Column.typeName()` and is passed through unquoted and unqualified into the 
generated `ALTER TABLE ... ADD COLUMN`, so mixed-case, reserved-word, and 
non-`search_path` type names break. Quoting the type name in the generated DDL 
looks like a reasonable direction; schema-qualifying it would also require 
knowing the type's namespace on the source side.
   
   To help narrow this down, could you share:
   
   - the SeaTunnel version(s) you tested and the PostgreSQL server version;
   - the full sink-side exception/log for the failing mixed-case range type 
case;
   - whether the user-defined types already exist in the sink database with the 
same name and schema, since the sink does not create the types itself.
   
   If you'd like to work on a fix, a PR would be very welcome.
   