On Sun, 26 Oct 2003 01:20:35 +0200 Juan Quintela <[EMAIL PROTECTED]> wrote:
> >>>>> "marc" == Marc Guise <[EMAIL PROTECTED]> writes: > marc> I read the post about Mdk 9.2 and LG on mandrakeusers.org. I have > cd-rw drive, marc> model HL-DT-ST GCE 8400b and I have Mdk 9.2rc2 running. > There are no problems marc> with my LG drive > > 21mdk just updated (vdanen should be doing the official update) fixes > that problem. Only LG plain CD-ROMS are affected. > > Later, Juan. > > PD. Yep, whoeved decided at LG that reusing for UPLOAD_FIRMAWARE > command FLUSH_CACHE comand should be shoot. Twice. While reading slashdot, I found this comment interesting (yes, that does happen on slashdot :-) ) http://slashdot.org/comments.pl?sid=83579&cid=7310813 "Why is Linux trying to send a flush cache command to a CD-ROM drive in the first place? That's a stupid thing to do. The ATAPI FLUSH CACHE command tells the device to flush its write cache to the media. A CD-ROM has no write cache, and can't write to any media. Of course, it's even more stupid for a drive to self-destruct when it gets a flush cache command..." Is this maybe 2 bugs "working together"? Using FLUSH_CACHE where it shouldn't, and have the cdrom reading that as UPLOAD_FIRMWARE -- Marcel Pol